Add to Cart
Ordering Information
PHF L PP 0500 40 G V
Series | Type | Material | Micron | Length | Outside | Sealing | End Caps | |||||||
PHF | L | PP | 0010 | =0.1μm | 1500 | =15μm | 20 | =20" | G | =Strengthen | V | =Viton | ZA | =Single-Ring(HFK) |
LH | PBT | 0100 | =1.0μm | 2000 | =20μm | 40 | =40" | M | =Melt | S | =Silicon | ZB | =Double-Ring(HFK) | |
K | GF | 0500 | =5.0μm | 4000 | =40μm | 60 | =60" | S | =Mesh | E | =EPDM | ZA | =一Type(HFM) | |
M | 1000 | =10μm | 7000 | =70μm | ZB | =十Type(HFM) | ||||||||
1000 | =100μm | none | =(HFL/HFLH) |
Power plant supplementary water condensation water Replace Parker High Flow Water Filter
PHF series large-flow filter cartridge adopts large diameter structure of 6 "with single end opening. The main body of filter cartridge is divided into two forms of melting blown and Pleated. The end cover and filter layer are welded by hot melt without any binder, so they have extensive chemical compatibility.
Application
Power plant condensation water filtration;
RO Pre-filtration, desalination pretreatment;
Biopharmaceutical industry pharmaceutical raw materials solvents, water filtration;
Food and Beverage process water treatment ;
Material Structure
Filter Material | PP:Deep Pleated PP/ Melt PP | FO:Organic Fiber | GF:Glass Fiber/Polyester |
Support/ Diversion | PP | Organic Fiber | Polyester |
End Cap | Fiberglass reinforced polypropylene | Fiberglass reinforced polypropylene | Fiberglass reinforced polypropylene |
Design Parameter
Size (Diameter*Length) | Design Flow (m3/h) | Maximum Flow (m3/h) | Filter Area (㎡) |
6"*20" | 15 | 40 | 2.6 |
6"*40" | 30 | 80 | 5.2 |
6"*60" | 45 | 120 | 7.8 |
Operating Characteristic
Maximum Temperature | PP:82°C FO:120℃ GF:121℃ |
Maximum Differential Pressure | PP:3.44bar / 21°C FO:3.44bar / 120°C GF:3.44bar / 121°C |